Chemours tests find “below standard” R410A

USA: Chemours has claimed that in analysis tests on five commercially available refrigerants on the US market, four failed to meet AHRI 700 specifications.

Over a 9-month period, Chemours claims it purchased five commercially available 25lb (11.3kg) cylinders of R410A from competing brands. The cylinders were then sampled and analysed under AHRI 700 testing conditions. Chemours claims that four out of five of the cylinders, labelled as “meeting industry standards,” in fact failed to meet the AHRI 700 specifications for blend composition, moisture, and non-condensables. 

AHRI 700 specifies acceptable levels of contaminants for fluorocarbon, hydrocarbon, and carbon dioxide refrigerants regardless of source and lists acceptable test methods. 

Although R410A is generally described as a 50/50 blend of R125 and “mildly flammable” R32, the AHRI 700 standard allows for 49.5%-51.5% of R125 and 48.5%-50.5% of R32. Two of the unnamed refrigerants tested by Chemours are said to have exceeded these specifications. The worst example comprised just 43.58% R32.

Results from the Chemours tests

Two other refrigerants exhibited contaminant levels above the accepted AHRI 700 limits. One, in particular, is said to have exceeded the specifications for both moisture and non-condensables. Chemours’ analysis is said to have revealed 3.06% by volume of non-condensables, more than twice the limit of less than 1.5%, and 11.7ppm of moisture, against the specification of less than 10ppm.

In a related investigation, Chemours says that several cylinders of competitor R404A and R407C refrigerants were also shown to contain what it describes as “low-quality” mixtures.

Chemours warns that bad compositions, non-condensables, and high moisture may lead to flammability risks, increased discharge temperature, damage to the compressor and metering device, poor cooling capacity and decreased system energy efficiency.

Latest News

10th February 2025

Carrier expands apprenticeship programme

UK: Carrier is building on the launch of its academy in Bracknell last year, and the appointment of an apprenticeship programme lead, by recruiting at least 17 apprentices this year.
10th February 2025

HPA publishes heat pump service checklist

UK: The Heat Pump Association (HPA) has introduced a guidance list of recommended minimum annual service checks for air-, ground- and water-source heat pumps. 
9th February 2025

Samsung stars at the Junction

UK: Samsung has delivered state of the art heating and cooling to a new bar, restaurant, cafe, and social workspace within Manchester Central, the city’s convention centre. 
9th February 2025

Loop offers heating and cooling retrofit option

UK: Panasonic has introduced its Aquarea Loop, a decentralised water-to-air heat pump designed for optimal energy efficiency that was first revealed at Chillventa last year.
9th February 2025

Scammer turns illegal refrigerant into water

POLAND: A warning issued by the police in Poland has exposed the level of ignorance of refrigerants and the F-gas regulations that exists in some European member states.
9th February 2025

More space available at HRS show

UK: Having previously raised the sold out signs for its forthcoming exhibition, the Hampshire Refrigeration Society (HRS) has now announced the availability of extra space.