BESA flags fire damper safety issue

UK: Inspections carried out by maintenance contractors have revealed that a “huge number” of fire and smoke dampers have been incorrectly installed in building ventilation systems.

The Building Engineering Services Association (BESA) has taken the unusual step in issuing an urgent warning after inspections found potential fire safety weakness in a large number of building ventilation systems.

It has issued an interim technical bulletin (VH001) ahead of a full update of its industry guidance for the Installation of Fire Dampers and Smoke Dampers (DW145) which is due for launch at the Association’s National Conference in October.

Head of technical Graeme Fox explained that many did not comply with manufacturers’ instructions and needed remedial action “without delay”.

“We have been alerted to the very dangerous practice of using self-drilling ‘tek’ screws which do not melt when temperatures rise during a building fire. This means spring-loaded dampers will not be released to contain the spread of fire within the zone and ensure the integrity of the fire stopping measure,” he said.

“Dampers must be secured by fusible fixings that allow the duct to break away otherwise the collapsing duct could pull the damper out of place and break the seal between the fire zones,” added Fox.

BESA’s technical committee sanctioned the technical bulletin, which is freely available on the Association’s website, to give contractors the information and appropriate terminology to alert clients to this potentially life-threatening problem.

The bulletin also updates the guidance and statutory requirements covering installation, testing and maintenance of fire dampers and smoke dampers including clients’ legal obligations to ensure their fire safety systems remain fit for purpose in line with the Regulatory Reform (Fire Safety) Order 2005 for England and Wales and the Fire Safety (Scotland) Regulations 2006.

It outlines the crucial role played by the penetration seal in ensuring the overall fire stopping integrity of an installation, the importance of maintenance teams being able to find and access dampers for testing and repair, and the need for designers and installers to seek expert advice from damper manufacturers.

“While this is clearly a very worrying situation, we can take some reassurance from the fact that this problem is being brought to our attention by the increasing frequency of fire damper inspections and tests as awareness grows of this extremely important issue,” said Fox.

“We would urge contractors to alert their clients immediately so all the necessary checks and repairs can be carried out.”

The document can reviewed and downloaded here.

Latest News

17th December 2024

Daikin forms Indian compressor JV

INDIA: Daikin’s Indian subsidiary is to form a joint venture with Taiwanese compressor company Rechi Precision to manufacture and sell rotary inverter compressors for the Indian air conditioning market.
17th December 2024

High GWP refrigerant increases in the atmosphere

CANADA: Researchers in Canada have found that HFC125, a high GWP gas and a major component of air conditioning refrigerant R410A, has increased exponentially in the past 20 years.
17th December 2024

MAN supply Europe’s largest river water heat pump

GERMANY: MAN Energy Solutions is supplying Europe’s largest heat-pump system to a district heating system in Cologne, drawing energy from the river Rhine.
17th December 2024

Urgent meeting sought over cellar cooler ban

UK: Graeme Fox, F-gas scheme director at Quidos, has sought an “urgent meeting” with DEFRA over its decision to include cellar coolers within the January 1 split system AC ban.
16th December 2024

Three tonnes of illegal HFCs seized in NZ

NEW ZEALAND: Authorities in New Zealand have reported the seizure of three tonnes of HFCs in an ongoing crackdown on illegal imports.
16th December 2024

Cellar cooler trade in uproar over F-gas ban

UK: Manufacturers and suppliers of cellar coolers are in uproar after UK government agencies declared that such systems using higher GWP refrigerants will be banned from January 1.